• Add Me To Mailing List
Österreicher Schweizer Deutsch English
  • Company
  • Technical Support
  • Sales & Hire
  • News, Events & Marketing
  • Contact Us
  • Sitemap

View Our Products By Category

  • Accessories
  • Audio Distribution Amplifiers
  • Audio Logging
  • Audio Monitors
  • Compressor/Limiters
  • Delays
  • Digital Audio Converters
  • Dolby ® Encoders
    & Decoders
  • Headphone Distribution Amplifiers
  • IP Streamers
  • Light/Power Controllers
  • Matching Converters
  • Meters
  • Microphone Amplifiers
  • Mixers
  • Monitor Controllers
  • Radio Studio Packages
  • Silence Detectors
  • Source Selectors
  • Speaker Mounts
  • Stereo to Mono Converters
  • Studio Furniture
  • Studio Illuminated Signs
  • Switchers
  • Synchronisers
  • Talkback & Comms
  • Telephone Hybrids
  • Time Server
  • Tone Generators
  • Video Distribution Amplifiers
  • Video Embedders/
    De-embedders
  • Voiceover & Commentary

View Our Distributed Products

DaySequerra Logo Ward Beck Logo

  • Loudness Metering/
    Measurement
  • Loudness Control
  • Surround 5.1/7.1 Decoder/UpMix
  • Surround 5.1/7.1 Encoder/DownMix
  • Surround 5.1/7.1 Encoder/Decoder
  • Mono To Stereo
    Processor
  • Low Bit Rate DAB+ Processors
  • Radio Tuner/Monitor


Prodys Logo

  • Prodys Codecs


  • Home >  
  • Software Downloads > 
  • DHY-03 Firmware Versions
Search 

Sonifex Software

DHY-03 Firmware Versions

DHY-03 Logo

DHY-03 V1.64

  • Alterations
    • Added Avaya Media Gateway Country Code [111] for Al Jazeera TV.

DHY-03 V1.61

  • Alterations
    • Line Reversal Min set to 35ms & ring timeout increased from 3->7 secs.

DHY-03 V1.59

  • Alterations
    • Changed Line Reversal - Now detects single reversal present for disconnect min parameter duration (ms).

DHY-03 V1.57

  • Alterations
    • Optional AGC on Receive Gain.

DHY-03 V1.55

  • Alterations
    • Country code fixes from V1.54

DHY-03 V1.54

  • Alterations
    • New Japan2 country-code with custom remote and impedance settings.

DHY-03 V1.45

  • Alterations
    • Added divert relay function to DHY-03 standard code (already present in EC)
    • Added ability to switch off divert relay function - parameter 2 bit 7 (i.e. add 0x80 to current set value) enables relay - this is default operation
    • Added debug info if boot fails - lower led alternates between first and last LED and top row of LEDs are lit with code value (for EC just red Tx/Rx LEDs alternate no code is shown)
      • 1 - Uart initialisation failed
      • 2 - Codec initialisation failed
      • 3 - Silabs chipset initialisation failed
      • 4 - Silabs front end chip fails to respond (Si3056)
      • 5 - Silabs line side chip fails to respond (Si3018)
    • added delay after divert relay release to ensure call is maintained if DHY-03 drops the call

DHY-03EC V1.45

  • Alterations
    • RX and TX LED's had been swapped in a prior change restored to correct values

DHY-03 V1.43

  • Alterations
    • RX and TX LED's had been swapped in a prior change restored to correct values

DHY-03 V1.43

  • Alterations
    • Altered New Zealand Disconnect cadences

DHY-03 V1.41

  • Alterations
    • Add rev of Silabs chipset version no.

DHY-03 V1.40

  • Alterations
    • New CC parameters:Display_Type, Adaption_Differential, Adaption_Response

DHY-03 V1.32

  • Alterations
    • CC's for AVAYA have new settings

DHY-03 V1.31

  • Alterations
    • Japan disconnect set to Line Reverse
    • Fix LINE_OUTPUT double precision mult io_mac

DHY-03 V1.30

  • Alterations
    • Changed limiter calculation of signal received from line

DHY-03 V1.29

  • Alterations
    • Added Line In to Tele Out Jumper Mode

DHY-03 V1.28

  • Alterations
    • JP2 Jumper Function non-operative - fixed

DHY-03 V1.27

  • Alterations
    • Distortion on telephone limiter when noise gate disabled

DHY-03 V1.21

  • Alterations
    • Added Avaya disconnect type 375/375ms 400Hz
    • Disconnect tone levels multiplied by 4 for finer control (requires any User Tones previously defined to have the treshold level set 4 times higher)
  • Bug Fixes
    • Wrong User Disconnect Tones were previous set by SCi

DHY-03 V1.19

  • Alterations
    • New settable line_overload param (P27 for current set and P52,77,102,127,152, 177 for Telephone Interface user sets)
    • New DT_PERMANENT disconnect type for permanent line hold
    • Added Country Code 118 for Broadcast Bionics/Avaya with permanent line hold

DHY-03 V1.14

  • Alterations
    • Added BB/Avaya as country code 119
    • Added Avaya disconnect tone - 400Hz 375msec On/Off cadence
    • Default disconnect time extended to 500msecs
  • Bug Fixes
    • Cadence disconnect bug fixed

DHY-03 V1.11

  • Initial Release

Sonifex Only The 											Best

Where To Order

  • In The UK
  • In The Rest Of The World

View Our Products By Brand

  • DHY-03
  • HY-03
  • Net-Log
  • openGear
  • Phone In 6
  • Pro Audio Streamers
  • Redbox
  • Reference Monitors
  • S0
  • S1
  • S2
  • S2 Solutions
  • SignalLED
  • Talkback &
    Commentary
Sonifex contact details Sonifex Logo www.sonifex.co.uk +44 (0)1933 650 700 sales@sonifex.co.uk

Sonifex Ltd. 61 Station Road, Irthlingborough, Northants, NN9 5QE, UK. Tel: +44 (0)1933 650700 Fax: +44 (0)1933 650726 EMail: sales@sonifex.co.uk